Zones: |
8 – 32 wired, wireless or RISCO Bus, in any combination |
Partitions |
: 4 |
Groups per partition |
: 4 |
Zone resistance |
: Fully selectable |
Remote zone diagnostics |
: Voltage and resistance measurement on all wired zones |
Zone loop response |
: 1msec, 10msec, 400 msec, 1 sec, 1/2 hour to 4 hours |
Additional inputs |
: Bell tamper, Box tamper |
Programmable outputs |
: 4 onboard (3*100mA opto-relays + 1A relay) expandable to 14 |
User codes |
: 16 |
Event log |
: 500 |
Keypads |
: 4 wired, 2 wireless (one-way) |
Wireless Keyfobs |
: 16 |
Proximity Key Readers |
: 8 |
Follow-me destinations |
: 16 |
Communication |
: PSTN onboard, Plug-in IP or modem, Plug-in GSM/GPRS or integrated KP, Long Range Radio programmable from the LightSYS™ keypad (Installed on the Bus within the main enclosure) |
Digital Voice Module |
: Full voice menu guide, two-way remote listen-in and talk, Pre-recorded or user-recordable messages for all zones, partitions and outputs, Remote operations such as acknowledge event, arm/disarm, activate outputs, etc. |
Reporting formats |
: Contact ID, SIA level 2 & 3, IP/GSM Receiver, Long Range Radio formats |
PC Cable connector |
: RS232 for Configuration Software |
PS Input |
: 90-264 VAC, 50-60Hz |
PS output / Main board input 14.4 VDC / 1.5A |
|
Main board output |
: 800mA Aux current, 500mA siren driver |
Dimensions |
: (Height x Width x Depth) 288mm x 254mm x 90mm (11.3” x 10.0” x 3.54“) Place for Main, Power Supply, 7Ah Battery, IP and GSM/GPRS modules (wireless receiver, voice module, zone expanders, output expanders, long range radio) |